SJWM-13C-25C Modular Plastic Single Jet Water Meter
Compatible with multiple communication modules
Optical Port, M-BUS, RS-485, Pulse output, LoRa RF, LoRaWAN, NB-IoT, 4G (CAT 1)
Single-jet, Dry-dial, Magnetic drive, Anti-magnetic Protection
Available for cold water (50°C)
Sizes: DN15 to 25 mm (½” – 1”).
Body material: Composite plastic
MAIN TECHNICAL DATA
DN15 | DN20 | DN25 | ||||
Q4 (Qoverload) m³/h | 3. 125 | 3. 125 | 5 | 5 | 7.875 | 7.875 |
Q3 (Qmax/permanent) m³/h | 2.5 | 2.5 | 4 | 4 | 6.3 | 6.3 |
Q2 (Qtransitional) m³/h | 0.05 | 0.025 | 0.08 | 0.04 | 0.126 | 0.063 |
Q1 (Qmin) m³/h | 0.03125 | 0.015625 | 0.05 | 0.025 | 0.07875 | 0.039375 |
Start Flow Rate m³/h | 0.01 | 0.005 | 0.014 | 0.007 | 0.02 | 0.012 |
Dynamic Range | R80 | R160 | R80 | R160 | R80 | R160 |
Min Reading(m³) | 0.0001 | |||||
Max Reading(m³) | 99,999 | |||||
Accuracy Class | Class B, Class C, Class 2 ( R80, R100, R160 ) | |||||
Standard | ISO4064 / OIML R49 | |||||
Measured Medium | Water | |||||
Maximum Permissible Error For The Lower Flow Rate Zone | ±5% | |||||
Maximum Permissible Error For The Upper Flow Rate Zone | ±2% for water having a temperature <30°C | |||||
Operating Temperature | -10°C~55°C | |||||
Accidental Temperature | -20°C~55°C | |||||
Max Loss(∆P) | Δp63 | |||||
Max Pressure(MAP) | MAP16 | |||||
Environmental Classification | Class B | |||||
Protection Class | IP68 | |||||
Material | Composite plastic | |||||
The Installation Senstivity | U0/D0 | |||||
Climatic and Mechanical | M1 | |||||
Communication | Optical Port, M-BUS, RS-485, Pulse output, LoRa RF, LoRaWAN, NB-IoT, 4G (CAT 1) | |||||
Installation Direction | Horizontal | |||||
Power Source | Lithium batteries | |||||
Module Battery Lifetime | 10-15 years | |||||
Historical Storage Data | 1080 hours, 180 days, 24 months | |||||
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN | Length(L) | Width(B) | Height(H) | Connecting Thread D | Weight Kg |
(mm) | mm | ||||
15 | 110 | 80 | 80 | G 3/4B | 0.35 |
20 | 130 | 85 | 80 | G 1B | 0.62 |
25 | 160 | 90 | 80 | G1 1/4B | 0.90 |
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Working pressure:≤1.6Mpa